Model FHE-15K Pacman Style Load Cell
|
|
|
Custom designed to install directly into a “Gerhart Owen” style
measuring head |
|
|
Load cell is a direct replacement for older hydraulic style units |
|
|
High sensitivity and excellent linearity provides years of trouble free
operation |
|
|
Eliminates cumbersome hydraulic hoses in the truck |
|
|
Temperature compensated electronics are not effected by severe climate
changes |

|
|
 |
|
Component |
Specifications |
|
Accuracy |
+- o.25% |
|
Operating Temperature |
-40 C to + 60 C |
|
Safe Overload |
100% |
|
Full Scale Output |
3.0mV/V @ Full Load |
|
Maximum Excitation |
15 Vac or DC |
|
Bridge Resistance |
350Q Normal |
|
Sheave Sizes |
n/a |
|
|
|
|
|
 |
|
|
|
|
|